Achtung! Bitte verwenden Sie die Firmware-Datei nur in Verbindung mit der CCU2 ab Version 2.29.22 Please note: Only use the firmware file in connection with the CCU2 from version 2.29.22 Changelog: HmIP-WTH-2 Version 1.8.000 - 20170915 ---------------------------------------------------------------------------------------- Version: Application: 1.8.000 Bootloader: 1.10.000 Library: 1.20.004 ** Related Hardware * 1434158F, 1434177A ** Bugfix * Correction in Paging-Module HMOS-Library Catched erros which could occure after an OTAU update to a newer paging module. * Correction for the Optimum Start Stop function After activating the optimum start stop function it is now executed correctly. ** Modification * Change to Version 1.8.000 Parameter extension for installer solution. With the help of the new parameter "DISABLE_MSG_TO_AC" all transmissions to the central address are suppressed. Also to the status receiver address if this is the same as the central address. Version 1.6.000 - 20170721 ---------------------------------------------------------------------------------------- Version: Application: 1.6.000 Bootloader: 1.10.000 Library: 1.20.003 ** Related Hardware * 1434158F, 1434177A ** Bugfix * Expansion for inclusion condition. If parameter changes have been made to the device before the inclusion, the device can only be included if a factory reset has been performed on the device before. * Correction for set point temperature update after weekprogram configuration. If window open is detected (extern/intern) and during this time a new week program is transmitted to the device, the device updated the set point temperature after window close by using the new week program set point temperature. * Correction when changing from auto mode to manu mode. When changing from auto mode to manu mode and boost is active, boost is abort. * The date and time are cyclically synchronized with the access point. In order that date and time are be synchron in system, the data is retrieved every 6 hours at Access point. * Extension for the Quick Veto Function. If the quick veto function is active, the remaining time is transferred in the status telegram. * Behavior after aborting the factory reset. If the factory reset is aborted or not executed until the end, the device performs a reboot after the termination or after the timeout. * Abort of Quick Veto by "Duration = 0". If Quick Veto is active, Quick Veto can be aborted by the radio command "Duration = 0". The device answers the radio telegram with an "Ack". ** Modification * Change to Version 1.6.000 Version 1.4.004 - 14.02.2017 ---------------------------------------------------------------------------------------- Version: Application: 1.4.004 Bootloader: 1.8.000 Library: 1.8.004 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * Bug fixing in temperature week program If one daily temperature profiles consist of only one switch time point, the switch time point is skipped by midnight of the next day. ** Modification * Change to Version 1.4.004 Version 1.4.003 - 31.01.2017 ---------------------------------------------------------------------------------------- Version: Application: 1.4.003 Bootloader: 1.8.000 Library: 1.8.004 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * Improved handling at quick-veto: Function is communicated to the link partner via a DEC-Command with "Duration-Time". ** Modification * Change to Version 1.4.003 Version 1.4.002 - 27.01.2017 ---------------------------------------------------------------------------------------- Version: Application: 1.4.002 Bootloader: 1.8.000 Library: 1.8.004 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * After troubleshooting with fix V1.4.001 no more cyclic messages were sent after a manual operation. ** Modification * Change to Version 1.4.002 Version 1.4.001 - 24.01.2017 ---------------------------------------------------------------------------------------- Version: Application: 1.4.001 Bootloader: 1.8.000 Library: 1.8.004 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * RF-Data-Communication Improvement: New data packages will not be sent until the current data transmission has finished. ** Modification * Change to Version 1.4.001 * Function extension: Implementation of Quick-Veto-Function (Default: inactive) Version 1.4.000 - 13.12.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.4.000 Bootloader: 1.8.000 Library: 1.8.004 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * The Application_Sequence_Number for TIME_INFO_REQUEST is increment after sending. * If the device wait for incoming data, it don't responce to other requests. * "Sa" and "Su" symbols are displayed during the weekend profile setting. * Time profile "Sunday" is accepted. * Time profile can be read out. ** Modification * Change to Version 1.4.000 Version 1.2.002 - 31.08.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.2.002 Bootloader: 1.8.000 Library: 1.16.001 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * After troubleshooting with fix V1.2.001 it was no longer recognized that a MIOB is in the system. ** Modification * Change to Version 1.2.002 Version 1.2.001 - 26.08.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.2.001 Bootloader: 1.8.000 Library: 1.16.001 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * If the FAL send a Direct Execution Command with Humidity limiter state "True", the device is not change from cooling mode to heating mode ( if cooling is activ ). ** Modification * Change to Version 1.2.001 Version 1.2.000 - 10.08.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.2.000 Bootloader: 1.8.000 Library: 1.16.001 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * The antenna symbol is not flashing when the communication does take place indirectly via a router. * If Party-Mode active, the device send in Pairing-Mode no Status-Messages to address 0x000000. ** Modification * Change to Version 1.2.000 * Party/Holiday function is distributed by FAL to link partner. Version 1.0.013 - 24.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.013 Bootloader: 1.8.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * If the device is paired with a FAL, Full-RX-Mode is not activ for 3 minutes after power-up. ** Modification * Change to Version 1.0.013 Version 1.0.012 - 17.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.012 Bootloader: 1.8.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * Heating/Cooling symbol is shown to the display, after a FAL link partner is created in inclusion mode. * The Boost-Function is possible, if the device is linked with a eTRV or a switch actor. * Mode-Change in inclusion mode is send to the link partners. ** Modification * Change to Version 1.0.012 Version 1.0.011 - 16.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.011 Bootloader: 1.8.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * Some modification for the pairing mode to realization the definite pairing description. ** Modification * Change to Version 1.0.011 Version 1.0.010 - 13.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.010 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Modification * Change to Version 1.0.010 Version 1.0.009 - 13.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.009 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * By sending a "DEC" or a "Conditional Switch Command" the App-Sequence-Counter is only increment one time. * Pairing mode can't activated if the device is included. * In Party-Mode the Weekday of the End-Date is shown correctly. * If the device is linked with a Remote-Control-Unit and the Parameter "ON_TIME" is set, the temperature "TEMPERATURE_RC" is hold minimum for this time (also the time is > 1 Minute). * First long button press for factory reset, is 4 second. * Heating-Symbol in LCD is only visible if a FAL is linked with device. * If the actual temperature < 4.0°C, manual button and encoder operating is possible. ** Modification * Change to Version 1.0.009 * The device accepted the temperature range from -10.0 °C to 60.0°C, by other temperature show send an error. Version 1.0.008 - 03.06.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.008 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * By changing time and date the switching weekprogram points are always observed ( Time change > 5 Minutes ). ** Modification * Change to Version 1.0.008 Version 1.0.007 - 31.05.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.007 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * In pairing mode link partner problems should not send to the status receiver address. * If the communication to the FAL is lost the antenna symbol in the display is flashing (Frequency 1Hz). * Affects only WTH-2: Fix incorrect advertisment in LCD 'dAy'. * In the Menu "Weekprogram Setting" the momentous time has always be greater than the previous time. ** Modification * Change to Version 1.0.007 * The Boost-Function is only possible, if the device is linked with a eTRV or a switch actor. * Channel Parameter 46, 48, 49 of FAL are skipped in FAL-Parameter-Change-Menu, because in pairing mode they are not needed. * Modify Default Values: DEFAULT_LIST1_TEMPERATURE_MINIMUM to 5.0°C and DEFAULT_LIST1_TEMPERATURE_MAXIMUM to 30.0° Version 1.0.006 - 17.05.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.006 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D (ALPHA-IP-RBG) * 1644394A, 1434177A (HmIP-WTH-2) ** Bugfix * The last byte in the status-info-frame for the status receiver was missing. * Fix problem in the menu-mode "FAL", if no FAL is paired with the RBG (-> always show bars on the display). ** Modification * Change to Version 1.0.006 * Extension the pairing function (only for completeness); * Modify / Change the status information, instead of "Valve Status" send a "Binary Information". Version 1.0.005 - 27.04.2016 ---------------------------------------------------------------------------------------- Version: Application: 1.0.005 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D ** Bugfix ** Modification * Change to Version 1.0.005 * Modification in production test-function. Version 1.0.004 - earlier ---------------------------------------------------------------------------------------- Version: Application: 1.0.004 Bootloader: 1.9.000 Library: 1.16.000 ** Related Hardware * 1624363D --- END OF FILE ---